Altronix T3M77LXK3 16-Door Altronix/Mercury Access and Power Integration Kit, Trove3TM3 with (2) AL1024ULXB2, (2) ACMS8, (2) PDS8, (2) VR6, RBS2
SKU
T3M77LXK3
Model No
T3M77LXK3
was $2,979.95 Special Price $2,924.00
Product Highlights
- Voltage: 115VAC, 60Hz, 4.2A max
- Input: 115VAC is present
- DC Output: Powered
- Battery: Discharged or not connected
- AC Failure: Form ″C″ contacts

Speak to an expert
The Altronix T3M77LXK3 is a comprehensive 16-door access and power integration kit designed for seamless operation with Mercury hardware. This kit features robust power solutions and factory-installed wire management, making it ideal for demanding security applications. With ample dual voltage outputs, battery backup options, and compatibility with multiple Mercury partners, the T3M77LXK3 ensures reliable performance and efficient installations.
Altronix T3M77LXK3 Access Control Features
- Two (2) AL1024ULXB2 Power Supply/Chargers: Provides stable 24VDC output with overvoltage protection, enhancing system reliability.
- Battery Backup (not included): Ensures continuous operation during AC loss with options for 12AH to 65AH capacity, maintaining security integrity.
- Supervision: Offers AC and battery failure notifications via Form “C” contacts, allowing for timely maintenance.
- Indicators LED: Clear status indicators for input AC, DC output, and battery connectivity, simplifying troubleshooting.
- Two (2) VR6 Voltage Regulators: Regulates voltage output to 12VDC with surge suppression, protecting sensitive equipment.
- Two (2) ACMS8 Dual Input Access Power Controllers: Independently controlled outputs provide flexible power management for both fail-safe and fail-secure applications.
- Two (2) PDS8 Dual Input Power Distribution Modules: Offers versatile output selection and servicing options, enhancing usability.
- Environmental Specifications: Designed to operate in a wide temperature range and high humidity, ensuring consistent performance in various conditions.
Altronix T3M77LXK3 Detailed Specifications
| Feature | Details |
| Input Voltage | 115VAC, 60Hz, 4.2A max |
| Main Fuse | 5A / 250V |
| Output Voltage | 24VDC, 10A @ 24VDC continuous max |
| Battery Type | Sealed lead acid or gel type (12AH / 12VDC recommended) |
| AC Failure Supervision | Form “C” contacts |
| Temperature Range | Operating: 0° C to 49° C; Storage: -20° C to 70° C |
| Relative Humidity | 85% +/- 5% |
| BTU/Hr | 289 BTU/Hr |