Altronix T2M7LXK3D 8-Door Altronix/Mercury Access and Power Integration Kit
SKU
T2M7LXK3D
Model No
T2M7LXK3D
$1,541.00
Product Highlights
- Voltage: 115VAC, 60Hz, 4.2A max
- Failover: Upon AC loss, instantaneous
- DC Output: Powered
- Battery: Discharged or not connected
- Input PTC: 9A

Speak to an expert
Altronix T2M7LXK3D is an 8-door access and power integration kit that ensures reliable and robust control for demanding applications. This kit includes Altronix power supplies and pre-configured terminal blocks for Mercury hardware, providing ample dual voltage outputs and simplified field installations. With support for various Mercury partners, the T2M7LXK3D is designed to meet the needs of modern security systems, offering seamless integration of power and access control.
Altronix T2M7LXK3D Key Features
- Comprehensive Support: Compatible with numerous Mercury partners, providing versatile integration options.
- Power Supply: Features AL1024ULXB2 with 24VDC, delivering 10A continuous max power for efficient performance.
- Battery Backup: Includes 12AH sealed lead acid batteries, ensuring security during AC power loss with instantaneous failover.
- Temperature Resilience: Operating range of 0° C to 49° C, ensuring reliable performance in various environments.
- Indicators LED: Clear visual indicators for AC power, DC output, and battery status to enhance monitoring capabilities.
- Customizable Outputs: Eight independently controlled outputs allow for versatile setups based on security needs.
Altronix T2M7LXK3D Detailed Specifications
| Feature | Details |
| Power Supply | AL1024ULXB2, 24VDC, 10A continuous max |
| Main Fuse | 5A / 250V |
| Battery Capacity | 12AH / 12VDC (2 within enclosure) |
| Failover | Instantaneous upon AC loss |
| AC Failure Supervision | Form “C” contacts |
| LED Indicators | Input AC, DC Output, Battery Status |
| Output Voltage | 12VDC and/or 24VDC selectable |
| Operating Temperature | 0° C to 49° C (32° F to 120° F) |
| Storage Temperature | -20° C to 70° C (-4° F to 158° F) |
| Relative Humidity | 85% +/- 5% |
| BTU/Hr | 145 BTU/Hr |
There are no related videos.
Write Your Own Review
Manuals & Specifications
Tools & CalculatorsProduct Accessories