Altronix T2KE3316DV 16-Door Altronix/Kisi Access and Power Integration Kit - Trove2LU2 with (2) AL600ULXB, (2) ACM8CB
SKU
T2KE3316DV
Model No
T2KE3316DV
$1,139.95
Product Highlights
- Voltage: 12VDC or 24VDC selectable
- Current: 6A @ 12VDC or 24VDC continuous max
- Other: Filtered and regulated
- Capacity: 7AH / 12VDC (Up to 4 within enclosure); 12AH / 12VDC (up to 4 within enclosure); 40 AH / 65 AH (requires separate enclosure)
- Type: Sealed lead acid or gel type

Speak to an expert
Altronix T2KE3316DV kit consists of Trove2 enclosure, TLU2 Kisi/Altronix backplane with two (2) 12 or 24VDC @ 6A power supply/chargers, and two eight (8) PTC protected output access control modules. This kit also accommodates up to four (4) Kisi Pro Controllers for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
Altronix T2KE3316DV Access Power Integration Kit Features
- Power Supply Efficiency: Two (2) AL600XB220 Power Supply/Charger, providing filtered and regulated 12VDC or 24VDC power to reduce system instability.
- Modular Design: Compatibility with up to four (4) Kisi Pro Controllers allows for seamless scaling to manage up to sixteen (16) doors, perfect for growing facilities.
- Flexible Backup Options: Supports various battery types (sealed lead acid or gel type), ensuring reliable operation even during power failures.
- Easy Monitoring: With AC and battery failure indicators, users can quickly assess system health and respond proactively.
- Environmental Adaptability: Operating temperature range of 0° C to 49° C and a relative humidity tolerance of 85% ensures reliability in diverse conditions.
Detailed Specifications for Altronix T2KE3316DV
| Item | Details |
| Power Supply Type | Two (2) AL600XB220 |
| Input Voltage | 220VAC (198VAC-256VAC), 50/60Hz, 1.5A max |
| Output Voltage | 12VDC or 24VDC selectable |
| Output Current | 6A @ 12VDC or 24VDC continuous max |
| Battery Backup Capacity | 7AH / 12VDC (up to 4), 12AH / 12VDC (up to 4) |
| Supervision | AC Failure: Form “C” contacts, Battery: Form “C” contacts |
| Access Power Controllers | Two (2) ACM8CB |
| Output Control | Eight (8) independent PTC outputs, Fail-Safe and Fail-Secure options |
| Operating Temperature | 0° C to 49° C (32° F to 120° F) |
| Storage Temperature | -20° C to 70° C (-4° F to 158° F) |
| Relative Humidity | 85% +/- 5% |
| BTU/Hr (12VDC) | 74 BTU/Hr |
| BTU/Hr (24VDC) | 148 BTU/Hr |
| BTU/Hr (12VDC and 24VDC) | 111 BTU/Hr |
There are no related videos.