Altronix T2DK7F16D 16-Door Altronix/DIN Rail Access and Power Integration Kit
SKU
T2DK7F16D
Model No
T2DK7F16D
$1,170.00
Product Highlights
- 24VDC power supply/charger
- Accommodates any DIN Rail mountable products
- Low Battery and Battery Presence
- Low power shutdown
- 16 AWG galvanized steel backplane simplifies board layout and wire management
- Enclosure accommodates up to two (2) 12VDC/12AH batteries

Speak to an expert
Altronix T2DK7F16D is a comprehensive 16-Door Access and Power Integration Kit designed for efficient management of power and access control within a single enclosure. This kit features a Trove2 enclosure, a TDR2 Altronix/DIN Rail backplane, and includes a robust 24VDC @ 10A power supply, making it ideal for large installations. Its integrated design simplifies board layout, improves wire management, and significantly reduces installation time and labor costs.
Altronix T2DK7F16D Key Features
- Enclosure: Trove2 enclosure provides a sturdy and organized housing for up to 16 doors, enhancing system reliability.
- Power Supply: The eFlow104NTB power supply ensures a steady 24VDC @ 10A output, minimizing power interruptions.
- Access Control Modules: Includes sixteen PTC protected access control modules allowing for secure and controlled access across multiple entry points.
- Power Distribution Modules: Eight PTC protected power distribution modules facilitate efficient power management, further enhancing system functionality.
- Battery Backup: Supports battery systems for failover during AC loss, ensuring continuous operation of security systems.
- Temperature Range: Operates effectively within a wide temperature range of 0° C to 49° C, making it suitable for various environments.
Altronix T2DK7F16D Detailed Specifications
| Feature | Details |
|---|---|
| Input Voltage | 120VAC, 60Hz, 4.5A max. |
| Input Fuse | 6.3A/250V |
| Output Voltage | 24VDC. |
| Output Current | 10A. |
| Auxiliary Output | 1A (unswitched) |
| Battery Capacity | 12AH/12VDC (4 within enclosure); 40AH/65AH (requires separate enclosure). |
| Battery Type | Sealed lead acid or gel type. |
| Failover Time | Instantaneous upon AC loss. |
| AC Failure Supervision | Form “C” contacts. |
| Battery Supervision | Form “C” contacts. |
| Temperature Operating Range | 0° C to 49° C (32° F to 120° F). |
| Temperature Storage Range | -20° C to 70° C (-4° F to 158° F). |