Altronix T1AXK3F2SV 2-Door Altronix/Axis Access and Power Integration Kit
SKU
T1AXK3F2SV
Model No
T1AXK3F2SV
$657.92
Product Highlights
- Four (4) independently controlled PTC outputs:
- a) Four (4) Fail-Safe and/or Fail-Secure power outputs
- Form "œC " Relays rated 28VAC or VDC @ 2.5A
- b) Auxiliary power outputs (unswitched)
- c) Any combination of the above
- Output Fuses: 3A / 32V

Speak to an expert
Introducing the Altronix T1AXK3F2SV 2-Door Access and Power Integration Kit, a comprehensive solution designed to streamline your access control system while ensuring efficient power distribution. This kit features a Trove1 enclosure and a range of advanced components that simplify installation, reduce labor costs, and improve overall system robustness. With flexible voltage options and integrated battery backups, the T1AXK3F2SV ensures reliable operation for up to two doors in a single unit.
Altronix T1AXK3F2SV Access Control Features
- Easy Installation: Trove1 enclosure design simplifies board layout and wire management, significantly reducing installation time and labor costs.
- Flexible Power Supply: Choose between 12VDC or 24VDC output with a maximum current of 6A, adaptable for various access control applications.
- Battery Backup: Supports up to two 7AH batteries within the enclosure, providing instant failover upon AC loss to maintain system functionality.
- Fire Alarm Disconnect: Supervised options with latching or non-latching capabilities ensure compliance with safety regulations.
- Comprehensive Supervision: Monitors AC failure, battery status, and low power conditions to prevent system downtime.
- Comprehensive LED Indicators: Clear visual feedback for power presence and output status for easy troubleshooting.
Detailed Specifications for Altronix T1AXK3F2SV
| Feature | Details |
| Input Voltage | 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.5A |
| Input Fuse | 5A/250V |
| Output Voltage | Selectable 12VDC or 24VDC |
| Output Current | 6A continuous max |
| Auxiliary Output | Power-limited @ 1A (unswitched) |
| Battery Capacity | 7AH/12VDC (2 within enclosure); 40AH/65AH (requires separate enclosure) |
| Fire Alarm Disconnect | Supervised, with EOL: 10K Resistor |
| Temperature Operating Range | 0° C to 49° C (32° F to 120° F) |
| Storage Temperature Range | -20° C to 70° C (-4° F to 158° F) |
| Relative Humidity | 85% +/- 5% |
There are no related videos.
Write Your Own Review
Manuals & Specifications
Tools & CalculatorsProduct Accessories