Altronix STRIKEIT1V Panic Device Controller, BC300 Enclosure
SKU
STRIKEIT1V
Model No
STRIKEIT1V
$365.84
Product Highlights
- Manual testing to allow to tests battery conditions
- Adjustable panic release from 1 sec. to 30 secs
- Cam lock included
- Input 220VAC 60Hz, 4A
- Two (2) NO trigger inputs

Speak to an expert
The Altronix STRIKEIT1V Panic Device Controller is a cutting-edge dual channel controller engineered for managing high current surge locking devices with precision. It features adjustable relock delay timers for each lock output, enabling simultaneous or independent control of doors. With additional functionalities such as delayed follower relays for automatic door operators and un-switched auxiliary outputs for various devices, this controller ensures efficient power management. LED indicators and intelligent logic provide operational oversight and protection against accidental shorting, making it a reliable choice for security needs.
Altronix STRIKEIT1V Panic Device Controller Features
- Dual Channel Control: Simultaneous or independent control for two doors enhances flexibility in security management.
- Adjustable Relock Delay: Customize relock timings to suit specific scenarios, ensuring rapid response to emergencies.
- Follower Relay Functionality: Trigger external devices when outputs are activated, boosting operational versatility.
- Two Auxiliary Outputs: Provides power for peripherals like card readers and PIRs, streamlining installation and reducing wiring clutter.
- Fire Alarm Interface: Configurable options to integrate seamlessly with fire alarms, ensuring safety during emergencies.
- LED Status Indicators: Monitor system performance at a glance, eliminating guesswork in operational conditions.
- Battery Backup: Automatic switch-over to battery ensures constant operation during power failures, enhancing reliability.
Altronix STRIKEIT1V Panic Device Controller Detailed Specifications
| Input Voltage | 220VAC 60Hz, 4A |
| Outputs | Two (2) 20VDC to 26.4VDC lock outputs; 0.75A continuous supply; Auxiliary outputs rated at 0.75A |
| Battery Backup | Includes leads, charger for lead acid/gel batteries, switches to standby when AC fails |
| Temperature Range | Operating: 0° C to 49° C; Storage: -20° C to 70° C |
| Visual Indicators | Power, trigger input status, fire alarm disconnect, and low battery LEDs |
| Fire Alarm Disconnect | Normally Closed FACP trigger input with programmable options |
| Humidity | Relative Humidity 85% +/- 5% |
| Mechanical Features | Includes a cam lock, manual testing feature, adjustable panic release |
| Power Requirements | System AC input VA requirement: 880VA |