Altronix MAXIMAL5FDV Access Power Controller w/ Power Supply/Charger, 16 PTC Class 2 Relay Outputs
- Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2A)
- Filtered and electronically regulated outputs (built-in power supply)
- Thermal and short circuit protection with auto reset
- Filtered and electronically regulated outputs (built-in power supply)
- Thermal and short circuit protection with auto reset

Maximal5FDV Access Power Controller distributes and switches power to access control systems and accessories. It converts a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into sixteen (16) independently controlled 12VDC PTC protected outputs. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting equipment must be UL Listed.
Features
Altronix MAXIMAL5FDV Access Power Controller + Input Features
- Input: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.1A input
Altronix MAXIMAL5FDV Access Power Controller + Power Supply Input Options
- Common Inputs: Two (2) common power input for either ACM8CB and lock power (factory installed)
- Isolated Inputs: Two (2) isolated power inputs (external power supply is required). Current is determined by the power supply connected, not to exceed a maximum of 10A total
- Trigger Inputs: Sixteen (16) Access Control System trigger inputs
Altronix MAXIMAL5FDV Access Power Controller + Input Options
- NO Inputs: Sixteen (16) normally open (NO) dry trigger inputs
- Open Collector Inputs: Sixteen (16) open collector inputs
- Input Combination: Any combination of the above
Altronix MAXIMAL5FDV Access Power Controller + Output Features
- DC Outputs: 12VDC outputs
Altronix MAXIMAL5FDV Access Power Controller + Maximum Output Current
- Output Current: 12VDC @ 8.6A
- Independently Controlled Outputs: Sixteen (16) independently controlled outputs
Altronix MAXIMAL5FDV Access Power Controller + Output Options
- Filtered Outputs: Sixteen (16) Fail-Safe filtered power outputs
- Filtered Secure Outputs: Sixteen (16) Fail-Secure filtered power outputs
- Unswitched Outputs: Sixteen (16) auxiliary power outputs (outputs are rated 2A)
- Regulated Outputs: Filtered and electronically regulated outputs (built-in power supply)
- Protection: Thermal and short circuit protection with auto reset
Altronix MAXIMAL5FDV Access Power Controller + Fuse Ratings
- Power Supply Fuse: Power Supply input fuse rated @ 5A/250V
- Main Fuse: ACM8CB boards main fuse is rated at 10A. PTC protected outputs are rated @ 2.5A each
Altronix MAXIMAL5FDV Access Power Controller + Fire Alarm Disconnect Features
- Selectability: Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
Altronix MAXIMAL5FDV Access Power Controller + Fire Alarm Disconnect Input Options
- Contact Input: Normally open (NO) or normally closed (NC) dry contact input
- Polarity Reversal: Polarity reversal input from FACP signaling circuit
- Alarm Output Relay: Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC)
Altronix MAXIMAL5FDV Access Power Controller + Supervision
- AC Fail Supervision: AC fail supervision (form "C" contacts)
- Notification Trigger: Notification trigger is selectable for 30 seconds (factory set) or 2 hours
- Battery Supervision: Low battery and battery presence supervision (form "C" contact)
Altronix MAXIMAL5FDV Access Power Controller + Battery Backup
- Charger: Built-in charger for sealed lead acid or gel type batteries
- Automatic Switch Over: Automatic switch over to stand-by battery when AC fails
- Zero Voltage Drop: Zero voltage drop when unit switches over to battery backup (AC failure condition)
Altronix MAXIMAL5FDV Access Power Controller + Visual Indicators
- Triggered Outputs: Red LEDs indicate outputs are triggered (relays energized)
- FACP Disconnect: Green LED indicates FACP disconnect is triggered
- Input and Output Indicators: AC input and DC output LED indicators
Altronix MAXIMAL5FDV Access Power Controller + Electrical Specifications
| Temperature Operating | 0° C to 49° C (32° F to 120° F) |
| Temperature Storage | -20° C to 70° C (-4° F to 158° F) |