Altronix MAXFIT716AP 16 Door Fused Access Power Controller Kit - BC750 enclosure with AL1024ULXB2, (2) ACM8, PD16W
SKU
MAXFIT716AP
Model No
MAXFIT716AP
$701.57
Product Highlights
- Voltage: 24VDC from AL1024ULXB2
- Main Fuse: 10A / 32V
- Type: Sealed lead acid or gel type
- Fuse Rating: 15A/32VDC
- Failover: Upon AC loss, instantaneous

Speak to an expert
Altronix MAXFIT716AP 16 Door Fused Access Power Controller Kit offers a robust solution for managing power distribution in access control systems. This powerful controller efficiently converts 115VAC input to sixteen 24VDC outputs, all while providing necessary safety features such as fuse protection and relay controls. Its compatibility with a variety of access hardware ensures versatile application, and the inclusion of a fire alarm control panel interface enhances safety and functionality.
Key Features:
Altronix MAXFIT716AP Power Distribution Features
- High Capacity Power Supply: 24VDC output distributed across 16 fuse-protected channels ensures dependable operation for multiple access control devices.
- Independent Control: Each output can be activated independently, allowing for flexible management of access control equipment like mag locks and electric strikes.
- Emergency Features: FACP interface enables rapid emergency egress and alarm monitoring for enhanced safety measures.
- LED Indicators: Integrated LEDs provide clear status information for AC input, DC output, and battery status, helping to quickly diagnose operational conditions.
- Robust Environmental Specs: Designed to operate in a wide temperature range (0° C to 50° C) and high humidity environments for versatility across various installations.
Detailed Specifications for Altronix MAXFIT716AP
| Feature | Details |
|---|---|
| Input Voltage | 115VAC, 60Hz, 4.2A max |
| Input Fuse | 5A / 250V |
| Output Voltage | 24VDC, 10A @ 24VDC continuous max |
| Output Protection | Overvoltage protection, filtered and regulated |
| Back-up Battery Types | Sealed lead acid or gel type (not included) |
| AC/Battery Supervision | Form “C” contacts for AC failure and battery |
| Number of Outputs | 16 fuse-protected outputs |
| Relay Outputs | Fail-Safe/Fail-Secure configuration |
| Operating Temperature | 0° C to 50° C (32° F to 122° F) |
| Storage Temperature | -20° C to 70° C (-4° F to 158° F) |
| Relative Humidity | 85% +/- 5% |
| BTU/Hr Output | 145 BTU/Hr |
There are no related videos.
Write Your Own Review
Manuals & Specifications
Tools & Calculators