Altronix MAXFIT37E Dual Power Supply Expandable Power Systems
SKU
MAXFIT37E
Model No
MAXFIT37E
$662.95
Product Highlights
- Capacity: 12AH / 12VDC (Up to 4 within enclosure). 40 AH / 65 AH (requires separate enclosure)
- Type: Sealed lead acid or gel type
- Fuse Rating: 15A/32V
- Failover: Upon AC loss, instantaneous
- Fuse Rating: 15A/32V
- Failover: Upon AC loss, instantaneous

Speak to an expert
Altronix MaxFit37E Expandable Power Systems provide system designers and installers with optimum power choices and the highest levels of versatility. They provide 24VDC, and 12VDC or 24VDC simultaneously via two (2) single output power supply/chargers. Suit of features includes AC fail, low battery, and battery presence monitoring. Enclosure accommodates up to four (4) 12VDC/12AH batteries.
Features
Altronix MAXFIT37E Input Features
- Voltage: 115VAC 60Hz, 7.9A - Ensures compatibility with standard power supplies for reliable operation.
- Fusing: 5A/250V - Protects the system from overload and electrical faults.
Altronix MAXFIT37E Output Features
- 12VDC and/or 24VDC outputs: Provides flexibility to power various devices simultaneously.
Altronix MAXFIT37E Maximum Output Current Options
- A) 24VDC @ 10A: High current output for demanding applications.
- B) 12VDC or 24VDC @ 6A: Versatile options to support different system needs.
- Other: Over Voltage Protection. Filtered and regulated - Safeguards devices from voltage spikes and ensures clean power.
Altronix MAXFIT37E Back-up Battery (not included)
- Capacity: 12AH / 12VDC (Up to 4 within enclosure). 40 AH / 65 AH (requires separate enclosure) - Provides ample backup power to maintain system functionality during outages.
- Type: Sealed lead acid or gel type - Durable options that support reliable performance.
- Fuse Rating: 15A/32V - Ensures appropriate safety measures are in place.
- Failover: Upon AC loss, instantaneous - Guarantees immediate switch to backup power.
Altronix MAXFIT37E Supervision Features
- AC Failure: Form “C” contacts - Allows integration with alarm systems for real-time monitoring.
- Battery: Form “C” contacts - Additional monitoring feature for battery status.
Altronix MAXFIT37E Indicators (LED)
- Input: 115VAC is present - Clear indication of power availability.
- DC Output: Powered - Quick visual confirmation of output status.
- Battery: Discharged or not connected - Alerts users to battery issues promptly.
Altronix MAXFIT37E Temperature Specifications
- Operating: 0ºC to 49ºC (32ºF to 120ºF) - Suitable for a range of environments.
- Storage: - 20ºC to 70ºC ( - 4ºF to 158ºF) - Ensures safe storage conditions for longevity.
- Relative Humidity: 85% +/- 5% - Tolerant of humid conditions.
Altronix MAXFIT37E BTU/Hr. (approx.)
- 24VDC: 197 BTU/Hr - Efficient heat output during operation.
- 12VDC and 24VDC: 160 BTU/Hr - Manageable heat output for system longevity.
Altronix MAXFIT37E Detailed Specifications
| Input Voltage | 115VAC 60Hz |
| Input Current | 7.9A |
| Fusing | 5A/250V |
| Output Voltage | 12VDC / 24VDC |
| Max Output Current | 24VDC @ 10A / 12VDC or 24VDC @ 6A |
| Back-up Battery Capacity | 12AH / 12VDC (4 max) or 40 AH / 65 AH (separate enclosure) |
| Battery Type | Sealed lead acid or gel type |
| AC Fail Monitoring | Form “C” contacts |
| Temperature Operating Range | 0ºC to 49ºC (32ºF to 120ºF) |
| Storage Temperature Range | -20ºC to 70ºC (-4ºF to 158ºF) |
| Relative Humidity | 85% +/- 5% |
| BTU Output | 197 BTU/Hr (24VDC) / 160 BTU/Hr (12VDC and 24VDC) |