Altronix EFLOW3NX4DV Power Supply Charger, 4 PTC Class 2 Outputs, 12/24VDC @ 2A
SKU
EFLOW3NX4DV
Model No
EFLOW3NX4DV
$239.02
Product Highlights
- 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.1A
- Input fuse: 5A/250V
- 12VDC or 24VDC @ 2.0A supply current
- Outputs are rated @ 2A
- Auxiliary output rated @ 1A (unswitched)

Speak to an expert
Altronix eFlow3NX4DV Power Supply Charger is a reliable solution that converts a 220VAC input into four PTC protected outputs with the flexibility of selectable voltage (12VDC or 24VDC). With a total output current of 2A, it boasts several advanced features including fire alarm disconnect, overvoltage protection, and a low power disconnect to safeguard your stand-by batteries from deep discharge, making it an ideal choice for critical applications.
Features
Altronix eFlow3NX4DV Input Specifications
- Input Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz for versatile usability.
- Input Fuse: 5A/250V for enhanced protection against electrical overloads.
Altronix eFlow3NX4DV Output Features
- Output Type: Four (4) PTC-protected outputs (auto-resettable) ensuring safety and reliability.
- Selectable Voltage: 12VDC or 24VDC @ 2.0A supply current for flexibility in power supply options.
- Rated Outputs: Outputs are rated @ 2A for consistent performance.
- Auxiliary Output: Auxiliary output rated @ 1A (unswitched) for additional power needs.
- Overvoltage Protection: Essential safety feature to prevent damage from power surges.
Altronix eFlow3NX4DV Battery Backup Features
- Battery Charger: Built-in charger for sealed lead acid or gel type batteries streams power reliably.
- Seamless Transition: Automatic switch over to stand-by battery when AC fails with no interruption for continuous operation.
Altronix eFlow3NX4DV Supervision Features
- AC Fail Supervision: AC fail supervision (form "C" contacts) alerts for potential issues.
- Notification Trigger: Selectable notifications for 30 seconds or 2 hours to monitor system status.
- Battery Supervision: Battery fail and presence supervision (form "C" contacts) to ensure battery health.
- Low Power Shutdown: Prevents deep battery discharge by shutting down DC output terminals at critical voltage levels.
Altronix eFlow3NX4DV Fire Alarm Disconnect Features
- Supervised Fire Alarm: Fire Alarm disconnect (latching or non-latching) for enhanced safety and compliance.
Altronix eFlow3NX4DV Electrical Specifications
- Operating Temperature: 0° C to 49° C (32° F to 120° F) for operational reliability.
- Storage Temperature: -20° C to 70° C (-4° F to 158° F) for long-term durability.
- Humidity: Relative humidity of 85% +/- 5% tolerated for various environments.
Altronix eFlow3NX4DV BTU Ratings
- BTU/Hr (12VDC): 12 BTU/Hr indicating energy efficiency.
- BTU/Hr (24VDC): 25 BTU/Hr reflecting heat output.
- AC input VA requirement: 462VA ensuring optimal performance.
Altronix eFlow3NX4DV Visual Indicators
- AC Power LED: Green AC Power LED indicates 220VAC present for quick checks.
- LED Indicators: AC input and DC output LED indicators provide real-time feedback.
Altronix eFlow3NX4DV Additional Features
- Short Circuit Protection: Comprehensive protection against short circuits enhancing safety.
- Complete Package: Unit includes power supply, enclosure, battery leads, and cam lock for convenience.
| Feature | Details |
|---|---|
| Input Voltage | 220VAC (working range 198VAC - 256VAC), 50/60Hz |
| Input Fuse | 5A/250V |
| Number of Outputs | Four (4) PTC-protected outputs |
| Output Voltage Selection | Selectable for 12VDC or 24VDC |
| Output Current | Total 2A max |
| Overvoltage Protection | Yes |
| Automatic Switch Over | To stand-by battery when AC fails |
| Operating Temperature | 0° C to 49° C (32° F to 120° F) |
| Storage Temperature | -20° C to 70° C (-4° F to 158° F) |
| Humidity | 85% +/- 5% |
| AC input Requirement | 462VA |