Altronix MAXIMAL1RH Access Power Controller w/ Power Supply/Charger, 8 Fused Relay Outputs, 12/24VDC @ 4A, 115VAC, 2U
- 115VAC 60Hz., 1.9 amp
- Normally closed [NC] or normally open [NO] dry contact inputs (switch selectable)
- 12VDC @ 4 amp or 24VDC @ 3 amp total output current
- Eight (8) fuse protected outputs
- Thermal and short circuit protection with auto reset

Maximal 1RH rack mount access power controller distributes and switches power to access control systems and accessories. It converts a 115VAC 50/60Hz input into eight (8) independently controlled 12VDC or 24VDC fuse protected outputs. Outputs are activated by an normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the outputs.
Altronix MAXIMAL1RH Features
- 115VAC Input: Provides reliable power conversion with a 1.9 amp capacity ensuring efficient performance.
- Dry Contact Inputs: Normally closed [NC] or normally open [NO] inputs allow versatile integration with various access control systems.
- Output Options: 12VDC @ 4 amp or 24VDC @ 3 amp total output current to accommodate different hardware requirements.
- Multiple Outputs: Eight (8) fuse protected outputs enhance system reliability and protect devices from overcurrent.
- Safety Features: Thermal and short circuit protection with auto-reset to ensure continuous operation without manual intervention.
- Fire Alarm Reset Switch: Latching or Non-Latching options available for individual outputs, enhancing flexibility during emergencies.
- Remote Reset Capability: Facilitates easy management of latching fire alarm interface mode, improving operational efficiency.
- Status Indicators: Individual Output Status LEDs on the front panel for easy monitoring of system status.
- Charge Current: Maximum charge current of 0.7 amp ensures optimal battery management.
- Automatic Switch Over: Standby battery back-up when AC fails enhances reliability during power disruptions.
- AC Fail Supervision: Provides alerts via form 'C' contacts for proactive maintenance.
- Battery Supervision: Low battery and presence surveillance with form 'C' contact adds an additional layer of security.
- Secure Connections: Removable terminal blocks with locking screw flange for safe and easy wiring.
- Line Cord: 3-wire line cord designed for straightforward installation.
- Power Disconnect Circuit Breaker: Illuminated master power disconnect circuit breaker with manual reset ensures quick access during maintenance.
Altronix MAXIMAL1RH Specifications
| Input Voltage | 115VAC 60Hz |
| Input Current | 1.9 amp |
| Output Voltage | 12VDC / 24VDC |
| Output Current | 12VDC @ 4 amp / 24VDC @ 3 amp |
| Outputs | Eight (8) fuse protected |
| Protection Features | Thermal and short circuit |
| Fire Alarm Features | Latching or Non-Latching, Remote Reset |
| Status Indicators | Individual Output Status LEDs |
| Max Charge Current | 0.7 amp |
| Power Backup | Automatic switch over to stand-by battery |
| Supervision | AC fail, Low battery, Battery presence |
| Connection Type | Removable terminal blocks with locking screw flange |
| Line Cord | 3-wire |
| Included Features | Illuminated circuit breaker, manual reset |