Altronix MAXIMAL7F 16 Fused Relay Outputs Access Power Controller with Power Supply/Charger, BC800 Enclosure
- 120VAC 60Hz, 4.5 amp input
- Sixteen (16) Access Control System trigger inputs
- 24VDC outputs
- Maximum output current: 24VDC @ 9.2 amp
- Sixteen (16) independently controlled outputs

Altronix MAXIMAL7F Access Power Controller Features
The Maximal7F Access Power Controller distributes and switches power to access control systems and accessories. It converts a 120VAC 60Hz input into sixteen (16) independently controlled 24VDC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form "C" contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting equipment must be UL Listed.
Features
- 120VAC 60Hz, 4.5 amp input: Efficiently powers your access control systems with robust performance.
- Sixteen (16) Access Control System trigger inputs: Versatile connectivity for multiple access control devices.
- 24VDC outputs: Reliable voltage output tailored for access control applications.
- Maximum output current: 24VDC @ 9.2 amp: Supports high power needs of various access control hardware.
- Sixteen (16) independently controlled outputs: Customizable management for individual systems and devices.
- Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2.5 amp): Additional power supply options for auxiliary devices.
- Filtered and electronically regulated outputs (built-in power supply): Ensures stable and clean power delivery to connected devices.
- Thermal and short circuit protection with auto reset: Enhances safety and reliability by preventing potential damage.
- Power Supply input fuse rated @ 6.3 amp/250V: Provides necessary protection against overloads.
- ACM8 boards main fuse is rated at 10 amp: Ensures high-performance reliability of the main distribution board.
- Fused outputs are rated @ 2.5 amp each: Offers secure and controllable power distribution.
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs: Customizable emergency protocols for varied safety requirements.
- Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC): Reliable alarm monitoring and notification capability.
- AC fail supervision (form "C" contact): Provides immediate notification of power loss.
- Low battery and battery presence supervision (form "C" contact): Ensures system stays operational and alerts about battery status.
- Built-in charger for sealed lead acid or gel type batteries: Efficient power management with automatic charging capability.
- Maximum charge current 1.54 amp: Supports rapid battery charging to maintain uptime.
- Automatic switch over to stand-by battery when AC fails: Guarantees uninterrupted operation during power outages.
- Zero voltage drop when unit switches over to battery backup (AC failure condition): Maintains system integrity during transitions to backup power.
- Red LEDs indicate outputs are triggered (relays energized): Visual status indicators for quick reference.
- Green LED indicates FACP disconnect is triggered: Clear alerting mechanism for critical system conditions.
- AC input and DC output LED indicators: Simple visual feedback on system power status.
Altronix MAXIMAL7F Detailed Specifications
| Input Voltage | 120VAC 60Hz |
| Input Current | 4.5 amp |
| Output Voltage | 24VDC |
| Output Current | Maximum 9.2 amp |
| Number of Outputs | 16 Controlled Outputs |
| Auxiliary Outputs | 16 Unswitched Outputs (rated 2.5 amp) |
| Protection Features | Thermal and Short Circuit with Auto Reset |
| Main Fuse Rating | 10 amp |
| Stand-by Battery | Charger for Sealed Lead Acid or Gel Type |
| Alarm Monitoring | Form "C" Contact Outputs |
| LED Indicators | Red and Green LEDs for status |
Tools & Calculators