Altronix MAXIMAL5F 16 Fused Relay Outputs Access Power Controller with Power Supply/Charger, BC800 Enclosure
- 120VAC 60Hz, 3.5 amp input
- Sixteen (16) Access Control System trigger inputs
- 12VDC outputs
- 12VDC @ 8.6 amp
- Sixteen (16) independently controlled outputs

Altronix MAXIMAL5F Access Power Controller Features
The Maximal5F Access Power Controller distributes and switches power to access control systems and accessories. It converts a 120VAC 60Hz input into sixteen (16) independently controlled 12VDC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form "C" contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting equipment must be UL Listed.
Features
- Input Voltage: 120VAC 60Hz, 3.5 amp input for reliable power supply.
- Trigger Inputs: Sixteen (16) Access Control System trigger inputs allow enhanced control of the system.
- Output Voltage: 12VDC outputs provide stable power to access devices.
- Current Rating: 12VDC @ 8.6 amp ensures robust performance under load.
- Independently Controlled Outputs: Sixteen (16) outputs for precise management of multiple devices.
- Auxiliary Power Outputs: Sixteen (16) auxiliary outputs (unswitched) rated at 2.5 amp each for additional accessory connectivity.
- Regulated Outputs: Filtered and electronically regulated outputs deliver consistent performance from the built-in power supply.
- Protection Features: Thermal and short circuit protection with auto reset enhances safety.
- Fuse Ratings: Input and output fuses rated appropriately for user safety and equipment protection.
- Alarm Features: Fire Alarm disconnect is selectable per output, enhancing user flexibility.
- Relay Output: Alarm output relay indicates FACP input trigger, facilitating real-time monitoring.
- Supervision Contacts: AC fail, low battery, and battery presence supervision via form "C" contacts for comprehensive monitoring.
- Battery Charger: Built-in charger supports sealed lead acid or gel type batteries for backup power.
- Automatic Switch Over: Seamless transition to standby battery when AC fails ensures uninterrupted operation.
- Zero Voltage Drop: Prevents voltage loss during switch to battery backup, maintaining system integrity.
- LED Indicators: Red and green LEDs display output status and FACP disconnect, enabling easy monitoring and troubleshooting.
- AC/DC Indicators: Visual monitoring of AC input and DC output via dedicated LED indicators.
Altronix MAXIMAL5F Detailed Specifications
| Input Voltage | 120VAC 60Hz |
| Input Current | 3.5 amp |
| Number of Outputs | 16 |
| Output Voltage | 12VDC |
| Output Current | 8.6 amp |
| Auxiliary Outputs | 16 outputs rated at 2.5 amp each |
| Protection | Thermal and short circuit with auto reset |
| Fire Alarm Disconnect | Selectably for any or all outputs |
| Relay Output Rating | 1 amp 28VDC |
| Battery Charger Type | Sealed lead acid or gel |
| Max Charge Current | 1.54 amp |
| LED Indicators | Red for trigger, Green for FACP disconnect |
| AC Fail Supervision | Form "C" contact |
| Weight | Not specified |
| Dimensions | Not specified |