Altronix MAXIMAL33RD Access Power Controller w/ Power Supply/Chargers, 16 PTC Class 2 Relay Outputs, Dual 12/24VDC P/S @ 6A each, 115VAC, 2U
- 115VAC 60Hz., 3.8 amp
- Normally closed [NC] or normally open [NO] dry contact inputs (switch selectable)
- Sixteen (16) PTC protected outputs
- Maximum current per ACM8R-M output is 2 amp
- Individually selectable Mag Lock/Strike (Fail-Safe, Fail-Secure) solid state fuse protected outputs

Maximal 33RD rack mount access power controller distributes and switches power to access control systems and accessories. It converts a 115VAC 50/60Hz input into sixteen (16) independently controlled 12VDC and/or 24VDC PTC protected outputs. Outputs are activated by an normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the outputs.
Altronix MAXIMAL33RD Access Power Controller Features
- Power Input: 115VAC 60Hz., 3.8 amp - Provides reliable power supply for efficient operation.
- Trigger Inputs: Normally closed [NC] or normally open [NO] dry contact inputs (switch selectable) - Offers flexibility for various control systems.
- Output Protection: Sixteen (16) PTC protected outputs - Ensures safety and longevity of devices connected.
- Current Output: Maximum current per ACM8R-M output is 2 amp - Supports a broad range of access control devices.
- Operational Modes: Individually selectable Mag Lock/Strike (Fail-Safe, Fail-Secure) solid state fuse protected outputs - Enhances versatility in security setups.
- Safety Features: Thermal and short circuit protection with auto reset - Prevents damage from faults in the system.
- Fire Alarm Reset: Latching or Non-Latching fire alarm reset switch individually selectable for each output - Simplifies emergency management.
- Remote Capabilities: Remote reset capability for latching Fire Alarm Interface mode - Facilitates easy management from afar.
- Status Indicators: Individual Output Status LEDs located on the front panel - Provides visual feedback for monitoring.
- Charge Current: Maximum charge current 0.7 amp - Efficient battery maintenance.
- Battery Backup: Automatic switch over to stand-by battery when AC fails - Ensures uninterrupted operation during power outages.
- Zero Voltage Drop: Zero voltage drop when unit switches over to battery backup (AC failure condition) - Guarantees stable operations under adverse conditions.
- Supervision: AC fail supervision (form “C” contact) - Alerts users to power issues timely.
- Battery Monitoring: Low battery and battery presence supervision (form “C” contact) - Ensures batteries are functioning correctly.
- Connections: Removable terminal blocks with locking screw flange - Facilitates secure and easy installation.
- Line Connectivity: 3-wire line cord - Provides a grounded connection for safety.
- Disconnect Features: Illuminated master power disconnect circuit breaker with manual reset - Easy management of the power supply.
Altronix MAXIMAL33RD Detailed Specifications
| Feature | Details |
| Power Input | 115VAC 60Hz., 3.8 amp |
| Trigger Inputs | Normally closed [NC] or normally open [NO] dry contact inputs (switch selectable) |
| Output Protection | Sixteen (16) PTC protected outputs |
| Current Output | Maximum current per ACM8R-M output is 2 amp |
| Operational Modes | Individually selectable Mag Lock/Strike (Fail-Safe, Fail-Secure) solid state fuse protected outputs |
| Safety Features | Thermal and short circuit protection with auto reset |
| Fire Alarm Reset | Latching or Non-Latching fire alarm reset switch individually selectable for each output |
| Remote Capabilities | Remote reset capability for latching Fire Alarm Interface mode |
| Status Indicators | Individual Output Status LEDs located on the front panel |
| Charge Current | Maximum charge current 0.7 amp |
| Battery Backup | Automatic switch over to stand-by battery when AC fails |
| Zero Voltage Drop | Zero voltage drop when unit switches over to battery backup (AC failure condition) |
| Supervision | AC fail supervision (form “C” contact) |
| Battery Monitoring | Low battery and battery presence supervision (form “C” contact) |
| Connections | Removable terminal blocks with locking screw flange |
| Line Connectivity | 3-wire line cord |
| Disconnect Features | Illuminated master power disconnect circuit breaker with manual reset |