Altronix MAXIMAL1RD Access Power Controller w/ Power Supply/Charger, 16 PTC Class 2 Relay Outputs, 12/24VDC @ 4A, 115VAC, 2U
- 115VAC 60Hz., 1.9 amp
- Normally closed [NC] or normally open [NO] dry contact inputs (switch selectable)
- 12VDC @ 4 amp or 24VDC @ 3 amp total output current
- Sixteen (16) PTC protected outputs
- Maximum current per ACM8R-M output is 2 amp

Maximal 1RD rack mount access power controller distributes and switches power to access control systems and accessories. It converts a 115VAC 50/60Hz input into sixteen (16) independently controlled 12VDC or 24VDC PTC protected outputs. Outputs are activated by an normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the outputs.
Altronix MAXIMAL1RD Access Power Controller Features
- Input Voltage: 115VAC 60Hz., 1.9 amp – Provides a stable power source for consistent operation.
- Relay Inputs: Normally closed [NC] or normally open [NO] dry contact inputs (switch selectable) – Offers flexibility in integration with various access control systems.
- Output Current: 12VDC @ 4 amp or 24VDC @ 3 amp total output – Supports multiple access control devices with adequate power supply.
- PTC Protected Outputs: Sixteen (16) PTC protected outputs – Ensures safety and protection against overloads for connected devices.
- Output Current Limitation: Maximum current per ACM8R-M output is 2 amp – Allows for efficient power distribution without compromising safety.
- Output Configuration: Individually selectable Mag Lock/Strike (Fail-Safe, Fail-Secure) solid state fuse protected outputs – Provides versatility in operation modes depending on security needs.
- Protection Features: Thermal and short circuit protection with auto reset – Enhances reliability of the power system during unexpected conditions.
- Fire Alarm Reset: Latching or Non-Latching fire alarm reset switch individually selectable for each output – Faciliates compliance with fire safety regulations.
- Remote Reset: Remote reset capability for latching Fire Alarm Interface mode – Enhances convenience for system management during emergencies.
- Output Status Indication: Individual Output Status LEDs located on the front panel – Provides visual confirmation of output status for easy monitoring.
- Charge Current: Maximum charge current .7 amp – Supports efficient charging of backup systems.
- Battery Backup: Automatic switch over to stand-by battery when AC fails – Ensures continuous operation even during power outages.
- Zero Voltage Drop: Zero voltage drop when unit switches over to battery backup (AC failure condition) – Maintains uninterrupted power for sensitive devices.
- Supervision Contacts: AC fail supervision (form “C” contact) – Alerts users to power issues for proactive management.
- Battery Supervision: Low battery and battery presence supervision (form “C” contact) – Ensures optimal battery performance and readiness.
- Terminal Blocks: Removable terminal blocks with locking screw flange – Simplifies installation and maintenance of connections.
- Power Cord: 3-wire line cord – Ensures a safe and reliable power supply connection.
- Circuit Breaker: Illuminated master power disconnect circuit breaker with manual reset – Enhances user safety and ease of operation.
Altronix MAXIMAL1RD Detailed Specifications
| Input Voltage | 115VAC 60Hz, 1.9 amp |
| Relay Inputs | Normally closed [NC] or normally open [NO] (switch selectable) |
| Output Voltage | 12VDC @ 4 amp / 24VDC @ 3 amp |
| Number of Outputs | Sixteen (16) PTC protected outputs |
| Max Current per Output | 2 amp |
| Protection Type | Thermal and short circuit protection with auto reset |
| Fire Alarm Reset | Latching or Non-Latching individually selectable |
| Remote Reset | Yes |
| Output Status LEDs | Yes, located on front panel |
| Battery Backup | Automated switch over |
| Zero Voltage Drop | Yes |
| AC Fail Supervision | Form “C” contact |
| Battery Supervision | Low battery presence supervision |
| Terminal Blocks | Removable with locking screw flange |
| Power Cord | 3-wire line cord |
| Circuit Breaker | Illuminated master power disconnect with manual reset |