Altronix ACM8 Access Power Controller, 8 Fused Relay Outputs, FAI, Board
- 12 to 24 volt AC
- 8 Outputs
- Electric Strikes
- Magnetic Door Holders
- Emergency Egress

Altronix ACM8 Access Power Controller Features
Altronix ACM8 distributes one (1) 12 to 24 volt AC or DC input over eight (8) independently controlled fuse protected outputs. The outputs can also be configured as dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. It will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both fail-safe and fail-secure modes. The ACM8 is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two totally independent power sources, one (1) providing power for board operation and the other for lock/accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, HVAC Shutdown, Elevator Recall or may be used to trigger other auxiliary devices. The fire alarm disconnect can be configured for the following modes; a) Eight (8) outputs affected or b) Four (4) outputs affected and four (4) outputs unaffected (50/50 mode).
Features
- Input Voltage Range: 12 to 24 volts AC or DC, ensuring compatibility with a wide range of access control systems.
- Independently Controlled Outputs: 8 outputs allow for flexible power distribution to multiple devices, enhancing security application options.
- Dry Contact Configuration: Outputs can be configured as dry form "C" contacts, facilitating integration with various systems.
- Fail-Safe and Fail-Secure Modes: Outputs can operate in both modes to meet specific security needs.
- Emergency Egress Functionality: Enables smooth evacuation and safety compliance in emergencies.
- Comprehensive Monitoring: Features alarm monitoring capabilities for real-time system oversight.
Altronix ACM8 Access Power Controller Detailed Specifications
| Input Voltage | 12 to 24 volts AC or DC |
| Outputs | 8 independently controlled, fuse protected |
| Output Configuration | Dry form "C" contacts |
| Fail-Safe / Fail-Secure | Configurable for both operating modes |
| Power Source Options | Single source for both board and locking devices or dual independent sources |
| FACP Interface | Supports Emergency Egress, Alarm Monitoring, and more |
| Fire Alarm Disconnect Modes | Affects all 8 outputs or 50/50 mode |